Efficacy of CA(OH)2 removal as an intra-duct medication comparing two irrigation techniques

Authors

DOI:

https://doi.org/10.35381/s.v.v6i2.2135

Keywords:

Technology, Dental, Orthodontics, Dental Equipment. (Source, DeCS).

Abstract

Objective: To analyze the efficacy of CA(OH)2 removal as an intraconduit medication by comparing two irrigation techniques. Method: Type of research applied by manual irrigation. Conclusion: It is estimated that for a better result in the removal of intra-duct medication, as well as smear Layer, an adequate protocol of final irrigation with 10 ml of sodium hypochlorite per duct, followed by irrigation with physiological saline, and activation of EDTA for 3 minutes, if done manually and from 30 seconds to 1 minute if done ultrasonically, should be carried out. Similarly, it is considered that for future studies the effectiveness of irrigation with Waterpik and manual dynamic activation used in the clinic can be evaluated, since this device is much more economical compared to ultrasound and superior results could be obtained than with the manual technique.

Downloads

Download data is not yet available.

References

Consolaro A, Miranda DAO, Consolaro RB. Orthodontics and Endodontics: clinical decision-making. Dental Press J Orthod. 2020;25(3):20-29. doi:10.1590/2177-6709.25.3.020-029.oin

Zafar K, Jamal S, Ghafoor R. Bio-active cements-Mineral Trioxide Aggregate based calcium silicate materials: a narrative review. J Pak Med Assoc. 2020;70(3):497-504. doi:10.5455/JPMA.16942

Gilbert B, Luebke RG, Jeansonne BG, Henderson JA. Calcium hydroxide in endodontics: a review. J La Dent Assoc. 1981;39(1):12-15.

Zinman EJ. Calcium Hydroxide. J Am Dent Assoc. 2020;151(8):553. doi:10.1016/j.adaj.2020.06.005

Dias-Junior LCL, Castro RF, Fernandes AD, Guerreiro MYR, Silva EJNL, Brandão JMDS. Final Endodontic Irrigation with 70% Ethanol Enhanced Calcium Hydroxide Removal from the Apical Third. J Endod. 2021;47(1):105-111. doi:10.1016/j.joen.2020.09.017

Song W, Li S, Tang Q, Chen L, Yuan Z. In vitro biocompatibility and bioactivity of calcium silicate based bioceramics in endodontics (Review). Int J Mol Med. 2021;48(1):128. doi:10.3892/ijmm.2021.4961

Engar RC. More on Calcium Hydroxide in Endodontics. J Am Dent Assoc. 2020;151(8):554. doi:10.1016/j.adaj.2020.06.007

Hemalatha S, Srinivasan A, Srirekha A, Santhosh L, Champa C, Shetty A. An in vitro radiological evaluation of irrigant penetration in the root canals using three different irrigation systems: Waterpik WP-100 device, passive irrigation, and manual dynamic irrigation systems. J Conserv Dent. 2022;25(4):403-408. doi:10.4103/jcd.jcd_162_22

Dhaimy S, Imdary S, Dhoum S, Benkiran I, El Ouazzani A. Radiological Evaluation of Penetration of the Irrigant according to Three Endodontic Irrigation Techniques. Int J Dent. 2016;2016:3142742. doi:10.1155/2016/3142742

van der Sluis LW, Versluis M, Wu MK, Wesselink PR. Passive ultrasonic irrigation of the root canal: a review of the literature. Int Endod J. 2007;40(6):415-426. doi:10.1111/j.1365-2591.2007.01243.x

Moreira RN, Pinto EB, Galo R, Falci SGM, Mesquita AT. Passive ultrasonic irrigation in root canal: systematic review and meta-analysis. Acta Odontol Scand. 2019;77(1):55-60. doi:10.1080/00016357.2018.1499960

Crozeta BM, Chaves de Souza L, Correa Silva-Sousa YT, Sousa-Neto MD, Jaramillo DE, Silva RM. Evaluation of Passive Ultrasonic Irrigation and GentleWave System as Adjuvants in Endodontic Retreatment. J Endod. 2020;46(9):1279-1285. doi:10.1016/j.joen.2020.06.001

Donnermeyer D, Wyrsch H, Bürklein S, Schäfer E. Removal of Calcium Hydroxide from Artificial Grooves in Straight Root Canals: Sonic Activation Using EDDY Versus Passive Ultrasonic Irrigation and XPendo Finisher. J Endod. 2019;45(3):322-326. doi:10.1016/j.joen.2018.11.001

Capar ID, Ozcan E, Arslan H, Ertas H, Aydinbelge HA. Effect of different final irrigation methods on the removal of calcium hydroxide from an artificial standardized groove in the apical third of root canals. J Endod. 2014;40(3):451-454. doi:10.1016/j.joen.2013.10.019

Wigler R, Dvir R, Weisman A, Matalon S, Kfir A. Efficacy of XP-endo finisher files in the removal of calcium hydroxide paste from artificial standardized grooves in the apical third of oval root canals. Int Endod J. 2017;50(7):700-705. doi:10.1111/iej.12668

Published

2022-08-15

How to Cite

Cárdenas-Naranjo, J. K., Rojas-Uribe, T. M., Romero-Fernández, A. J., & Arroyo-Lalama, E. M. (2022). Efficacy of CA(OH)2 removal as an intra-duct medication comparing two irrigation techniques. Revista Arbitrada Interdisciplinaria De Ciencias De La Salud. Salud Y Vida, 6(2), 529–536. https://doi.org/10.35381/s.v.v6i2.2135

Most read articles by the same author(s)

1 2 3 4 5 6 7 8 9 > >>