Objective: To identify the dimensional stability and reproduction of anatomical details in alginate impressions. Method: Descriptive observational study, the population consisted of 10 dental students of UNIANDES - Ecuador. Conclusion: The dimensional stability of the alginate impressions made in patients with different casting times has been notoriously variable, and even more so if we specify the canine and second molar teeth, which is where this stability will be better appreciated. We will be able to observe that thanks to the manipulation of different sizes of mouths in the patients we had a possible hypothesis of variable size in time.

Downloads

Download data is not yet available.

References

Roca-Sacramento C, Ibarra-Vásquez L, Amado-Chavez JD, Saucedo-García A, Castro-Rodríguez Y. Influencia de las condiciones del tiempo y almacenamiento en la estabilidad dimensional de los moldes fabricados a partir de hidrocoloides irreversibles [Influence of time and storage conditions on the dimensional stability of molds made from irreversible hydrocolloids]. Odontol Sanmarquina. 2018;21(2):81.

He Q, Tong T, Yu C, Wang Q. Advances in Algin and Alginate-Hybrid Materials for Drug Delivery and Tissue Engineering. Mar Drugs. 2022;21(1):14. https://doi.org/10.3390/md21010014

Adamiak K, Sionkowska A. State of Innovation in Alginate-Based Materials. Mar Drugs. 2023;21(6):353. https://doi.org/10.3390/md21060353

Kang SH, Lee JW, Lim SH, Kim YH, Kim MK. Dental image replacement on cone beam computed tomography with three-dimensional optical scanning of a dental cast, occlusal bite, or bite tray impression. Int J Oral Maxillofac Surg. 2014;43(10):1293-1301. https://doi.org/10.1016/j.ijom.2014.06.009

Muchhala M, Unozawa S, Kadempour A, Froum SJ. A Novel Design of a Pick-up-Type Impression Coping. Compend Contin Educ Dent. 2020;41(6):336-339.

Yuzbasioglu E, Kurt H, Turunc R, Bilir H. Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health. 2014;14:10. https://doi.org/10.1186/1472-6831-14-10

Yerramsetti A, John A, Sherigar P. Establishing the posterior palatal seal area by using a clear acrylic resin custom tray during the definitive impression: A dental technique. J Prosthet Dent. 2023;130(5):674-676. https://doi.org/10.1016/j.prosdent.2021.12.014

Fokkinga WA, van Uchelen J, Witter DJ, Mulder J, Creugers NH. Impression Procedures for Metal Frame Removable Partial Dentures as Applied by General Dental Practitioners. Int J Prosthodont. 2016;29(2):166-168. https://doi.org/10.11607/ijp.4540

Kamimura E, Tanaka S, Takaba M, Tachi K, Baba K. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques. PLoS One. 2017;12(6):e0179188. https://doi.org/10.1371/journal.pone.0179188

Fernandes DS, Anasane NS, Jagtap AK. Splinting Open Tray Impression Copings Using Long Shank Carbide Burs during Definitive Impression: A Dental Technique. J Contemp Dent Pract. 2022;23(5):566-568.

Molinero-Mourelle P, Lam W, Cascos-Sánchez R, Azevedo L, Gómez-Polo M. Photogrammetric and Intraoral Digital Impression Technique for the Rehabilitation of Multiple Unfavorably Positioned Dental Implants: A Clinical Report. J Oral Implantol. 2019;45(5):398-402. https://doi.org/10.1563/aaid-joi-D-19-00140

Agarwal S, Ashok V, Maiti S. Open- or Closed-Tray Impression Technique in Implant Prosthesis: A Dentist's Perspective. J Long Term Eff Med Implants. 2020;30(3):193-198. https://doi.org/10.1615/JLongTermEffMedImplants.2020035933

Fellows CM, Thomas GA. Determination of bound and unbound water in dental alginate irreversible hydrocolloid by nuclear magnetic resonance spectroscopy. Dent Mater. 2009;25(4):486-493. https://doi.org/10.1016/j.dental.2008.10.001

Iwasaki Y, Hiraguchi H, Iwasaki E, Yoneyama T. Effects of immersion disinfection of agar-alginate combined impressions on the surface properties of stone casts. Dent Mater J. 2016;35(1):45-50. https://doi.org/10.4012/dmj.2015-163

Peters MC, Tieleman A. Accuracy and dimensional stability of a combined hydrocolloid impression system. J Prosthet Dent. 1992;67(6):873-878. https://doi.org/10.1016/0022-3913(92)90605-a

Published

2024-02-01

How to Cite

Rosero-Pilco, D. S., Guadalupe-Chamorro, J. A., Santamaría-Chiriboga, F. A., & Granda-Macías, L. A. (2024). Dimensional stability and reproduction of anatomical details in alginate impressions. Revista Arbitrada Interdisciplinaria De Ciencias De La Salud. Salud Y Vida, 8(1), 1417–1424. https://doi.org/10.35381/s.v.v8i1.3947

Issue

Section

Original breve